Sensing element
Thermocouple type K, N, J, T, E.
Tolerance class 1 according to IEC 60584 (EN 60584)
Temperature range
-200 to +1150 °C, depending on thermocouple type,
sheath diameter and length
External sheath
AISI 316L or Inconel 600 (other material on request) seamless
semi-flexible sheath with mineral oxide filling
Can be manufactured in very long lengths (virtually unlimited)
Can be bended with a radius equal to 3 times the sheath diameter
Totally watertight
Diameter
6 mm by default: 3 - 4,5 and 8 mm
Process connection
Standard ½”BSP-M connector
Sliding connector available in option for diameter 8 - 6 -4,5 - 3mm probes
Connection head
Standard DIN type B head with M20 cable gland (other connection heads available on request)
Wiring
2-wire (single) or 4-wire (double thermocouple)
APPLICATIONS
Alternative to standard probes at high temperature,
Long reach probes or difficult installations with curves, bends or loops,
Whenever high mechanical resistance is required.
Options
4-20 mA or 0/10V transmitter (insulated, non insulated, HART, etc.) can be built in if connection head or ambient temperature does not exceed 75 °C
Ex Design 